AR2000 owners info.
This set has receive capability from 500kHz to 1300MHz, no gaps with modes AM, Narrow FM, Wide FM.
All receiver information i.e. frequency, modulation mode, memory channel, is displayed on a LCD. A lamp is also provided to back illuminate the LCD. On pressing the LIGHT button, the lamp will light and stay lit for 6 seconds.
A attenuator switch is provided at the top of the set (up='DX' / down='local') 10dB attenuation when set to 'local')
Memory is an EEPROM (i.e. no battery backup required) of 1000 memories held as 10 'banks' of 100. Further more there are 100 programmable search banks (i.e. programmed to search between two specific frequencies with a given mode and step (increment). Specific memories and banks can be 'locked out'
Operation:
(a) Manual Mode
(b) Memory Mode
(c) Scan Mode
(d) Search Mode
(a) Manual Mode:
(1) To enter a frequency:
Key in the digits.
(i.e. to receive 145.000 MHz
MANUAL - 145.000 - ENTER
or
MANUAL - 145. - ENTER
( if an invalid frequency is keyed the following will be displayed on the LCD: 'Fr. Err')
(a-2) Manually tuning the set.
To manually tune the set from the manually entered frequency just twist the rotary control on the top face of the cabinet. The increment is user defined (see below)
(a-3)To alter the frequency 'increment' or 'step':
This relates to the rotary tuning control, the default one being 12.5kHz. An increment can be selected of between 5 and 995 kHz but must be a multiple of 5kHz or 12.5kHz
INC (desired step in kHz) ENTER
i.e.
INC - 25 - ENTER
for a tuning step size of 0.025 MHz (25 kHz)
(a-4) To change modulation mode (AM//NFM/WFM)
Note: when you change mode while a memory bank number is showing, the setting of that memory bank may also be altered. It is recommended to key up mem. channel 000 (or any unused mem. channel) as a 'note pad' and used during manual operation.
Press AM/FM to select AM or Narrow FM of W-FM to select Wide Band FM.
(no need to press ENTER)
(b) Memory Mode
(b-1) To enter a displayed frequency and mode into memory.
MANUAL - PROG (memory bank, channel) ENTER
E.G. to enter the displayed freq. and mode into Memory bank 2, channel 30
MANUAL - PROG - 230 - ENTER
(b-2) To enter a new freq. and mode into memory.
Manual (freq. in MHz) ENTER (mod mode) PROG (mem. Bank, channel)
i.e. to enter 145.0375 MHz, Narrow FM mode into mem bank 5 and channel 31
MANUAL - 145.0375 - ENTER - FM - PROG - 531
(b-3) To recall a stored mem channel.
MANUAL BANK (mem bank, channel)
to recall the contents of mem bank 2 channel 30
MANUAL - BANK - 230
(b-4) To delete the contents of a stored mem channel.
MANUAL - CLEAR - ENTER - PROG - (mem bank and channel)
Ex To clear the mem contents of bank 2, channel 30
MANUAL - CLEAR - ENTER - PROG - 230
(b-5) Memory lockout
You can lockout a memory channel while in manual mode by first selecting the memory channel the press LOCKOUT. Lockout is confirmed by a flashing 'L.OUT' on the display. This is relevant to SCAN mode.
To reinstate the locked out channel, key in the channel in manual mode by keying in the channel location and pressing LOCKOUT again.
(b-6)Priority (Auxiliary) Channel.
Any of the 1000 available channels may be used as the Aux. When activated, the receiver will 'pop over' to the priority channel to check for activity regardless of the current freq. or mode.
To select the desired channel:
MANUAL AUX PROG (mem bank, channel) - ENTER
to select bank 6 channel 12 as the auxiliary:
MANUAL - AUX - PROG - 612 - ENTER
To activate or deactivate the Aux function:
press
MANUAL - AUX
(c) Scan mode
(c-1) To scan all memories:
press:
SCAN
The set will scan all programmed mem channels. The squelch control must be set to mute the background noise before the set will scan.
Problems:
If the receiver refuses to scan the bank you want and instead 'jumps' banks you may have accidentally previously set Program Bank Scan. To clear this problem key in the following:
SCAN - BANK - PROG - 0 - LIMIT - 9 - ENTER
(c-2) Program Scan Bank
To start scanning at a particular bank you can specify it as follows:
SCAN - BANK - (desired starting bank no.)
i.e. to start at Bank 6 enter:
SCAN - BANK - 6
(The receiver starts at bank 6 but will then move on to bank 7,8,9,0,1,2,3,4,5, and again.)
To program scan between specific scan Banks:
SCAN BANK PROG (start bank number) LIMIT (end bank number) ENTER
i.e. to scan between BANK1 and BANK 5:
SCAN - BANK - PROG - 1 - LIMIT - 5 - ENTER
To scan only one wanted bank: (i.e. bank 2)
SCAN- BANK- PROG - (wanted bank) LIMIT (wanted bank) ENTER
Memory LOCKOUT
If during scan the receiver stops on a mem channel that is not desired, you may press the LOCKOUT key to skip the channel during the Scan. This is confirmed by a flashing 'L.OUT' on the LCD.
To reinstate the channel before a future scan firstly go to manual mode key in the mem location and press LOCKOUT once. The flashing 'L.OUT' should disappear.
Memory Group Lockout
Choose the lowest channel number of the group you want to lockout.
For example to lockout the group between
MANUAL - BANK - 200 - LOCKOUT
MANUAL (The receiver now advances to the next memory) - LOCKOUT
MANUAL - LOCKOUT
MANUAL - LOCKOUT
MANUAL LOCKOUT
etc until the ten are reached.
(5) Memory bank lockout (All 100 memories of a particular bank)
MANUAL BANK (bank number, 00) BANK - LOCKOUT
i.e. to lockout memory bank 6 i.e. all memory locations between 600 and 699
MANUAL - BANK - 600 - BANK - LOCKOUT
N.B. In the above, keying in any number between 600 and 699 instead of 600 will have same effect.
To release a locked memory bank key the following:
MANUAL BANK (bank number, 00) -LOCKOUT
The flashing 'L.OUT' disappears from the display. Any channel which was individually locked out remains so.
Search Mode.
The set is capable of searching between 10 sets of user definable frequency limits known as Search banks. These are set at manufacture (and have legends i.e. Air band on the buttons 0-9) but any frequency ranges desired by the user can instead be programmed. In this mode the lower and upper limits are defined and the step size is specified (between 5kHz and 995kHz must be a multiple of 5kHz or 12.5 kHz.)
(4-d) To Search all Search banks
Press
SEARCH
(The receiver will search through Search Banks 0, 1, 2, .... 9, then start from bank 0 again.)
To start searching form a particular search bank:
SEARCH BANK (bank number)
e.g. : to start searching at Search Bank 7
SEARCH - BANK - 7
(the receiver will search Search Bank 7 then 8 ,9,0,1,2,3,4,5,6 and repeat.
To program a search of specific banks between Search Bank X and Search Bank Y
SEARCH BANK PROG (start Search Bank) LIMIT (end Search Bank) ENTER
Example to search between Bank 3 and Bank 6
SEARCH - BANK - PROG - 3 - LIMIT - 6 - ENTER
to search only one bank i.e. bank 7:
SEARCH - BANK - PROG - 7 - LIMIT - 7 - ENTER
it will repeatedly search Bank 7.
3 Search frequency lockout:
If during Search the set stops on a frequency that is not desired, press the LOCKOUT key to skip over the frequency. It will be skipped on future searches. Up to 100 frequencies may be locked out on each Search Bank range.
4b Search Bank lockout
SEARCH - BANK - (number) - BANK - LOCKOUT
To release a search Bank lockout key the following:
SEARCH - BANK - (number) - LOGOUT
6. Reprogramming Search Bank limits.
SEARCH - PROG - (start freq.) - LIMIT - (end frequency) - ENTER - (search step in kHz) - ENTER - - (mod. Mode) - ENTER - (bank number) - ENTER - SEARCH
7.Storing a frequency found by Search into memory.
Press
DELAY/HOLD
button so that 'HOLD' symbol appears on the display.
Press
ENTER
(type mem. bank, channel)
Example: the set stops at 74.000 MHz during a Search. To save this freq. (and its mod. Mode) onto Memory bank 2, channel 27
press
DELAY/HOLD - ENTER - 227
********************************************** Freq rang 500kHz to 1300MHz Sensitivity FM approx 0.5uV or better "across most of the range" AM approx 3uV or better "across most of the range" Mem scan speed: approx 20 channels per second Scan delay time: Approx 2 seconds Audio o/p >100mW at 10 % distortion Power consumption: Approx 80 mA standby, 85-100mA with audio size 170 x 35 x 65mm
THIS SECTION SERVICE PERSONNEL ONLY:
AR 2000 SCANNNER RECEIVER RESET INSTRUCTIONS
The AR2000 scanner has no external RESET facility. In the case of a 'hang' or corruption, reset the memory of the set in the following manner. With the set switched off, connect a diode between pins 13 (diode anode) and 51 (diode cathode) on the microprocessor.
Switch the set on and press the keys in the following order:
BANK - 1 - PROG - 0.5 - LIMIT - 49.995 - SEARCH - 556.325 - ENTER 2 - PROG - 50 - LIMIT - 107.995 - SEARCH - 556.325 - ENTER 3 - PROG - 108 - LIMIT - 169.995 - SEARCH - 556.325 - ENTER 4 - PROG - 170 - LIMIT - 286.995 - SEARCH - 556.325 - ENTER 5 - PROG - 287 - LIMIT - 599.995 - SEARCH - 249.125 - ENTER 6 - PROG - 800 - LIMIT - 1109.995 - [DOWN BUTTON] - 249.125 - ENTER 7 - PROG - 1110 - LIMIT - 1300 - [DOWN BUTTON] - 556.325 - ENTER 8 - PROG - 600 - LIMIT - 799.995 - SEARCH - 58.075 - ENTER
Switch off the set and disconnect the diode. The scanner is now reset and all memory banks empty. It is recommended that at least one frequency be keyed into each memory bank. Now reprogram each of the 10 search banks. i.e. SEARCH PROG (start frequency) LIMIT (stop frequency) ENTER (search step in kHz) ENTER (mode) ENTER (bank number) ENTER SEARCH
SEARCH - PROG - 2 - LIMIT - 30 - ENTER - 5 - ENTER - AM - ENTER - 1 - ENTER - SEARCH SEARCH - PROG - 88 - LIMIT - 108 - ENTER - 50 - ENTER - WFM - ENTER - 2 - ENTER - SEARCH SEARCH - PROG - 108 - LIMIT - 138 - ENTER - 25 - ENTER - AM - ENTER - 3 - ENTER - SEARCH SEARCH - PROG - 225 - LIMIT - 400 - ENTER - 50 - ENTER - AM - ENTER - 4 - ENTER - SEARCH SEARCH - PROG - 144 - LIMIT - 146 - ENTER - 12.5 - ENTER - FM - ENTER - 5 - ENTER - SEARCH SEARCH - PROG - 433 - LIMIT - 435 - ENTER - 25 - ENTER - FM - ENTER - 6 - ENTER - SEARCH SEARCH - PROG - 156 - LIMIT - 163 - ENTER - 25 - ENTER - FM - ENTER - 7 - ENTER - SEARCH SEARCH - PROG - 165 - LIMIT - 174 - ENTER - 12.5 - ENTER - FM - ENTER - 8 - ENTER - SEARCH SEARCH - PROG - 890 - LIMIT - 905 - ENTER - 12.5 - ENTER - FM - ENTER - 9 - ENTER - SEARCH SEARCH - PROG - 935 - LIMIT - 950 - ENTER - 12.5 - ENTER - FM - ENTER - 0 - ENTER - SEARCH
Reset and reprogramming is now complete.
(INFO CURRENT 1991)
(" A wire link could be used in place of a diode for reset on the AR2000 (Applicable to the AR1000 as well")
Breaktrough issues:
FM Broadcast band (88-108MHz) breakthrough is noted when the scanner is on WFM mode and is tuned to displayed frequencies which are 26.0 MHz or 47.45 Mhz (weaker response) below strong signals of the 88-108MHz FM band. This also occurs with displayed frequencies up to 297MHz